TLA(Total Laboratory Automation)

Laboratory Automation System

CLINILOG V4

  • CLINILOG V4 realizes high level integration.
  • Consisting the basic modules,
  • Sample Loading/Unloading and Conveyer Modules,
  • combined with Pre-analytical and Analytical modules and others.
  • The components can be modified for your own laboratory and modules from different fields or the same module can be added for higher throughput.
  • One-Stop Operation
  • Minimizes operator foot traffic and centralizes operation management.
  • Lessened load on operator shortens Turnaround Time and improves quality.
  • High Speed
  • CLINILOG V4 made high-speed performance possible without compromising throughput and integrity of test results.
  • Space Saving
  • Powerful high-speed system requires only minimal space.
  • Configurable system layout adapts to diverse customer needs.

  • 1. Random Access Archive (RAA)

    Double-story module with the capacity to hold 1,200 samples has a transfer speed of 1,000 samples/hr enabled by independent robotic arms for each set of drawers on left and right. Sample sorting by primary or secondary sample, or test item is configurable in the 24 rack space.

  • 2. Carrier Pool

    Buffer capacity of up to 50 sample carriers at a time allows samples to adjust timing before sending them to MPAM or other modules.

  • 3. intelligent Centrifuge Module (iCM)

    High throughput of 300 samples/hr loads samples in and out of centrifuge rotor efficiently, minimizing sample wait time. STAT samples are processed with priority.

  • 4. Managed Pre-Analysis Module (MPAM)

    Pre-analytical processing efficiency is enhanced by the maximum throughput of decapping, aliquoting, and sorting of 600 samples/hr (rubber top), 570 samples/hr, and 1,000 samples/hr respectively. Configuration of 2 modules further improves sample processing.

  • 5. Track Line

    Samples are transferred using a single carrier at a maximum speed of 700 mm/sec. Because samples are transferred individually only to the required analyzer, processing is efficient.

  • 6. Buffer

    Temporarily stores a maximum of 36 pre-analized samples and sends them to analyzers in prioritized order. Samples after sampling are also held and sent back for rerun or back to the unloading module if completed.

  • 7. Connector

    General Connectors and dedicated Connectors are available, connecting analyzers to the track system. Sample capacity of the Connector is based on the throughput of the connected analyzer to maintain processing capability and prioritization of STAT samples.

  • 8. Centralized Operative inTuitive Interface (COTi)

    Centralized management of multiple modules from one screen. Operation status and test results are check from one interface.

Communicates with the host computer and controls operation of all modules and measurement results.

* Specification and appearance may be changed without a preliminary announcement for product improvement.